github_osv/GHSA-66r6-rvv9-9x6m
Jenkins ElectricFlow Plugin missing permission check
A missing permission check in a form validation method in CloudBees CD Plugin allowed users with Overall/Read permission to initiate a connection test to an attacker-specified server with attacker-specified username and password.
Additionally, the form validation method did not require POST requests, resulting in a CSRF vulnerability.
This form validation method now requires POST requests and Overall/Administer permissions.
gitlab/maven/org.jenkins-ci.plugins/electricflow/CVE-2019-10332
Missing Authorization
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.