{"url":"http://public2.vulnerablecode.io/api/vulnerabilities/110182?format=json","vulnerability_id":"VCID-47n1-3c6t-2yeb","summary":"An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC.","aliases":[{"alias":"CVE-2025-34029"}],"fixed_packages":[],"affected_packages":[],"references":[{"reference_url":"https://api.first.org/data/v1/epss?cve=CVE-2025-34029","reference_id":"","reference_type":"","scores":[{"value":"0.05352","scoring_system":"epss","scoring_elements":"0.90313","published_at":"2026-06-12T12:55:00Z"},{"value":"0.05352","scoring_system":"epss","scoring_elements":"0.90283","published_at":"2026-06-11T12:55:00Z"}],"url":"https://api.first.org/data/v1/epss?cve=CVE-2025-34029"},{"reference_url":"https://www.exploit-db.com/exploits/48377","reference_id":"48377","reference_type":"","scores":[{"value":"9.4","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:T/P:M/B:A/M:M/D:T/2025-06-23T20:41:13Z/"}],"url":"https://www.exploit-db.com/exploits/48377"},{"reference_url":"https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163","reference_id":"detail?asid=32163","reference_type":"","scores":[{"value":"9.4","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:T/P:M/B:A/M:M/D:T/2025-06-23T20:41:13Z/"}],"url":"https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163"},{"reference_url":"https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections","reference_id":"edimax-ew-7438rpn-command-injections","reference_type":"","scores":[{"value":"9.4","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:T/P:M/B:A/M:M/D:T/2025-06-23T20:41:13Z/"}],"url":"https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections"},{"reference_url":"https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/","reference_id":"ew-7438rpn_mini","reference_type":"","scores":[{"value":"9.4","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:T/P:M/B:A/M:M/D:T/2025-06-23T20:41:13Z/"}],"url":"https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/"}],"weaknesses":[{"cwe_id":78,"name":"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","description":"The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component."}],"exploits":[],"severity_range_score":"9.4 - 9.4","exploitability":null,"weighted_severity":null,"risk_score":null,"resource_url":"http://public2.vulnerablecode.io/vulnerabilities/VCID-47n1-3c6t-2yeb"}