{"url":"http://public2.vulnerablecode.io/api/vulnerabilities/36438?format=json","vulnerability_id":"VCID-afz2-c9yc-wkct","summary":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.","aliases":[{"alias":"CVE-2024-12371"}],"fixed_packages":[],"affected_packages":[],"references":[{"reference_url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1714.html","reference_id":"advisory.SD1714.html","reference_type":"","scores":[{"value":"9.3","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:N/T:P/P:M/B:A/M:M/D:T/2024-12-18T19:58:35Z/"}],"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1714.html"}],"weaknesses":[],"exploits":[],"severity_range_score":"9.3 - 9.3","exploitability":null,"weighted_severity":null,"risk_score":null,"resource_url":"http://public2.vulnerablecode.io/vulnerabilities/VCID-afz2-c9yc-wkct"}