{"url":"http://public2.vulnerablecode.io/api/vulnerabilities/83920?format=json","vulnerability_id":"VCID-wtq8-k8vw-fycu","summary":"A vulnerability exists in SenseLive X3050’s web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information.","aliases":[{"alias":"CVE-2026-40431"}],"fixed_packages":[],"affected_packages":[],"references":[{"reference_url":"https://api.first.org/data/v1/epss?cve=CVE-2026-40431","reference_id":"","reference_type":"","scores":[{"value":"0.00034","scoring_system":"epss","scoring_elements":"0.10394","published_at":"2026-06-11T12:55:00Z"}],"url":"https://api.first.org/data/v1/epss?cve=CVE-2026-40431"},{"reference_url":"https://senselive.io/contact","reference_id":"contact","reference_type":"","scores":[{"value":"5.3","scoring_system":"cvssv3.1","scoring_elements":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"},{"value":"6.9","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:P/P:M/B:A/M:M/D:T/2026-04-24T16:49:38Z/"}],"url":"https://senselive.io/contact"},{"reference_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12","reference_id":"icsa-26-111-12","reference_type":"","scores":[{"value":"5.3","scoring_system":"cvssv3.1","scoring_elements":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"},{"value":"6.9","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:P/P:M/B:A/M:M/D:T/2026-04-24T16:49:38Z/"}],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"},{"reference_url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json","reference_id":"icsa-26-111-12.json","reference_type":"","scores":[{"value":"5.3","scoring_system":"cvssv3.1","scoring_elements":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N"},{"value":"6.9","scoring_system":"cvssv4","scoring_elements":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N"},{"value":"Track","scoring_system":"ssvc","scoring_elements":"SSVCv2/E:N/A:Y/T:P/P:M/B:A/M:M/D:T/2026-04-24T16:49:38Z/"}],"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"}],"weaknesses":[{"cwe_id":319,"name":"Cleartext Transmission of Sensitive Information","description":"The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors."}],"exploits":[],"severity_range_score":"5.3 - 6.9","exploitability":null,"weighted_severity":null,"risk_score":null,"resource_url":"http://public2.vulnerablecode.io/vulnerabilities/VCID-wtq8-k8vw-fycu"}